amp 
Logical Entity Name  amp 
Default Table Name  amp 
Definition  Summary information on an amplitude reading 

amp Columns 
ColumnName  Domain  Datatype  NULL  Definition 
commid    NUMBER(15, 0)  YES  Comment identification. This is a key used to point to free-form comments entered in the Remark relation. These comments store additional information about a tuple in another relation. Within the Remark relation, there may be many tuples with the same commid and different lineno, but the same commid will appear in only one other tuple among the rest of the relations in the database 
ampid(PK)    NUMBER(15, 0)  NO  Amplitude identification. Each amplitude is assigned a unique positive integer identifying it. This number is used in the AssocAmO relation along with the origin identifier to link Amp and Origin. This number is used also in the AssocAmM relation along with the magnitude identifier to link Amp and Netmag 
datetime    NUMBER(25, 10)  NO  The date of associated with information in the record, in true epoch format 
sta    VARCHAR2(6)  NO  Station code. This is the common code-name of a seismic observatory. Generally only three or four characters are used 
net    VARCHAR2(8)  YES  Unique network identifier. This character string is the name of a seismic network 
auth    VARCHAR2(15)  NO  The auth field specifies the source of the information. This may be a network identifier (FDSN or otherwise), or any other string indicating the source of the information in the record 
subsource    VARCHAR2(8)  YES  A second identifier to specify a unique source within the domain specified by auth 
channel    VARCHAR2(3)  YES  Channel name 
channelsrc    VARCHAR2(8)  YES  Domain for channel. This specifies what naming convention is used for the channel name (i.e. SEED, USGS, etc.) 
seedchan    VARCHAR2(3)  YES  SEED channel name. The first character denotes the band code, the second for the instrument code and the third represents the component code 
location    VARCHAR2(2)  YES  Describes the individual sites on an array station, operated by the same network operator 
iphase    VARCHAR2(8)  YES  Reported phase. This eight-character field holds the name initially given to a seismic phase. Standard seismological labels for the types of signals (or phases) are used (e.g., P, PKP, PcP, pP). Both upper and lower case letters are available and should be used when appropriate, for example, pP or PcP 
amplitude    DOUBLE PRECISION  NO  Amplitude in appropriate units for type 
amptype    VARCHAR2(8)  YES  Amplitude type 
units    VARCHAR2(4)  NO  Units of amplitude 
ampmeas    VARCHAR2(1)  YES  Amplitude measure 
eramp    NUMBER(5, 3)  YES  Uncertainty in amplitude measurement 
flagamp    VARCHAR2(4)  YES  This attribute is a flag to indicate whether amplitude is over P packet, S packet, entire waveform, etc 
per    NUMBER(10, 4)  YES  Signal period. This attribute is the period of the signal described by the amplitude record 
snr    DOUBLE PRECISION  YES  Signal-to-noise ratio. This is an estimate of the signal relative to that of the noise immediately preceding it 
tau    NUMBER(7, 4)  YES  Coda duration (F-P time) 
quality    NUMBER(2, 1)  YES  This attribute denotes the quality of an origin, an arrival, or a mechanism. 1.0 = good, 0.0 = bad 
rflag    VARCHAR2(2)  YES  This flag describes whether an observation was generated automatically, by a human, or has been finalized 
cflag    VARCHAR2(2)  YES  This flag indicates whether the amplitude value is below noise, on scale or clipped 
wstart    DOUBLE PRECISION  YES  Start of time window of amplitude measurement 
duration    DOUBLE PRECISION  YES  Duration of amplitude reading 
lddate    DATE  YES  Load date. Date and time that the record was created or last modified, in Oracle date datatype 

amp Foreign Keys 
Parent Table  Child Table  Type  Foreign Keys 
amp  assocamm  Identifying  ampid 
amp  assocamo  Identifying  ampid 

amp Check Constraints 
Check Constraint Name  CheckConstraint 
amp01  ampid > 0 
amp02  amplitude > 0 
amp03  ampmeas in ('0','1') 
amp04  amptype in ('C','WA','WAS','PGA','PGV','PGD','WAC','WAU','IV2','SP.3','SP1.0','SP3.0','ML100','ME100','EGY') 
amp06  eramp >= 0.0 
amp07  flagamp in ('P','S','R','PP','ALL','SUR') 
amp08  per > 0.0 
amp09  tau > 0.0 
amp10  units in ('c','s','mm','cm','m','ms','mss','cms','cmss','mms','mmss','mc','nm','e','iovs','spa','none') 
amp11  quality >= 0.0 and quality <= 1.0 
amp12  rflag in ('a','h','f','A','H','F') 
amp13  cflag in ('bn', 'os','cl','BN','OS','CL')